Question 1 of 37 Medium

In scientific measurement, accuracy refers to:

  1. A Repeatability of the results
  2. B Speed of measurement
  3. C Closeness to the true value
  4. D Number of observations

Correct answer: Closeness to the true value

Accuracy describes how close a measured value is to the true or accepted value. Repeatability relates to precision, making it the most tempting distractor.

Question 2 of 37 Medium

Precision in an experiment mainly indicates:

  1. A Correctness of a result
  2. B Large sample size
  3. C A complete absence of any human error
  4. D Consistency of repeated measurements

Correct answer: Consistency of repeated measurements

Precision refers to how closely repeated measurements agree with one another. A result may be precise without being accurate.

Question 3 of 37 Medium

A balance gives nearly identical readings each time but all differ from the true mass. This balance is:

  1. A Accurate but not precise
  2. B Neither accurate nor precise
  3. C Precise but not accurate
  4. D Both accurate and precise

Correct answer: Precise but not accurate

Closely grouped readings indicate high precision, while deviation from the true value shows poor accuracy. Accurate measurements would be close to the accepted value.

Question 4 of 37 Medium

Random errors mainly affect the:

  1. A Accuracy only
  2. B True value
  3. C The specific units of measurement
  4. D Precision of measurements

Correct answer: Precision of measurements

Random errors increase the spread of repeated measurements, reducing precision. Systematic errors are the main cause of reduced accuracy.

Question 5 of 37 Medium

Which practice is most effective in improving measurement precision?

  1. A Changing the measuring unit used
  2. B Ignoring unusual values
  3. C Taking repeated measurements
  4. D Using rounded numbers

Correct answer: Taking repeated measurements

Repeated measurements help reduce the effect of random errors and improve precision. Simply changing units does not improve measurement quality.

Question 6 of 37 Medium

A systematic error primarily reduces:

  1. A Precision
  2. B Sample size
  3. C Overall accuracy
  4. D Observation time

Correct answer: Overall accuracy

Systematic errors shift measurements consistently away from the true value, reducing accuracy. Precision may still remain high if the error is consistent.

Question 7 of 37 Medium

Which instrument characteristic most improves measurement accuracy?

  1. A Bright color
  2. B Large digital display
  3. C Proper calibration
  4. D Low weight

Correct answer: Proper calibration

Calibration ensures an instrument gives values close to the true measurement. Display size affects readability but not the inherent accuracy.

Question 8 of 37 Medium

A student records 25.0 cm instead of 24.97 cm due to rounding. This mainly introduces:

  1. A Systematic bias
  2. B Sampling error
  3. C Calibration error
  4. D Loss of precision

Correct answer: Loss of precision

Rounding reduces the level of detail in a measurement, decreasing precision. It does not necessarily introduce a systematic bias.

Question 9 of 37 Medium

Which action is most likely to reduce random error?

  1. A Using an uncalibrated measuring instrument
  2. B Ignoring repeated trials
  3. C Calculating the average of readings
  4. D Changing the experiment midway

Correct answer: Calculating the average of readings

Averaging repeated measurements reduces the influence of random fluctuations. Using an uncalibrated instrument introduces systematic error instead.

Question 10 of 37 Medium

An instrument that always reads 2°C higher than the actual temperature has:

  1. A Random error
  2. B Precision error
  3. C Observer bias only
  4. D Systematic error

Correct answer: Systematic error

A constant offset is a classic example of systematic error. Such an instrument may still produce very precise readings.

Question 11 of 37 Medium

Which of the following best improves measurement accuracy?

  1. A Calibrating the instrument
  2. B Increasing decimal places
  3. C Taking fewer readings
  4. D Estimating values visually

Correct answer: Calibrating the instrument

Calibration aligns measurements with accepted standards, improving accuracy. Adding decimal places without better measurements does not increase accuracy.

Question 12 of 37 Medium

A dartboard pattern with darts tightly grouped at the center represents:

  1. A Precise, inaccurate
  2. B Accurate but imprecise
  3. C Accurate and precise
  4. D Neither accurate nor precise

Correct answer: Accurate and precise

A tight cluster at the target center indicates both accuracy and precision. A tight cluster away from the center would be precise but inaccurate.

Question 13 of 37 Medium

Why are repeated measurements recommended in scientific experiments?

  1. A To eliminate all systematic errors
  2. B To change the accepted value
  3. C To increase instrument range
  4. D To improve reliability of results

Correct answer: To improve reliability of results

Repeated measurements improve the reliability of experimental results by reducing the influence of random errors. They do not eliminate systematic errors.

Question 14 of 37 Medium

Which situation demonstrates both high accuracy and high precision?

  1. A Measurements close together and near the true value
  2. B Measurements spread around the true value
  3. C Measurements close together but incorrect
  4. D Measurements widely scattered and far from the true value

Correct answer: Measurements close together and near the true value

Measurements that are both close to one another and close to the accepted value exhibit high precision and high accuracy. Closely grouped but incorrect values indicate only precision.

Question 15 of 37 Medium

A zero error in a measuring instrument mainly affects:

  1. A Precision
  2. B Accuracy level
  3. C Sample selection
  4. D Observation time

Correct answer: Accuracy level

Zero error introduces a constant offset, reducing accuracy. Precision may remain high because the error is consistent.

Question 16 of 37 Medium

Which measurement set is most precise?

  1. A 10.105, 9.805, 10.405 cm
  2. B 9.2, 10.8, 10.5 cm
  3. C 10.00, 10.01, 10.00 cm
  4. D 8.5, 10.2, 11.6 cm

Correct answer: 10.00, 10.01, 10.00 cm

The values 10.00, 10.01, and 10.00 cm are extremely close together, showing excellent precision. Whether they are accurate depends on the true value.

Question 17 of 37 Medium

Which statement about accuracy and precision is correct?

  1. A High precision always ensures high measurement accuracy
  2. B Accuracy is unaffected by calibration
  3. C Random errors improve precision
  4. D A result can be precise without being accurate

Correct answer: A result can be precise without being accurate

Measurements can be very consistent yet consistently incorrect, making them precise but inaccurate. Calibration is important because it directly affects accuracy.

Question 18 of 37 Easy

A rod's accepted length is 50.0 cm, and a student measures it as 49.0 cm. What is the percent error?

  1. A 2.0%
  2. B 1.0%
  3. C 0.02%
  4. D 4.0%

Correct answer: 2.0%

Percent error = |measured - accepted| / accepted x 100 = 1.0 / 50.0 x 100 = 2.0%. The 1.0% option mistakes the absolute difference of 1.0 cm for a percentage without dividing by the accepted value.

Question 19 of 37 Medium

How many significant figures are in the measurement 0.004050?

  1. A 3
  2. B 6
  3. C 4
  4. D 7

Correct answer: 4

Leading zeros only locate the decimal point, so the significant digits are 4, 0, 5 and the trailing 0 after the decimal, giving four. Answering 3 wrongly drops the trailing zero, which is significant because it follows a decimal point.

Question 20 of 37 Hard

A vernier caliper has 10 vernier divisions that span 9 main-scale divisions of 1 mm each. What is its least count?

  1. A 0.01 mm
  2. B 0.9 mm
  3. C 1 mm
  4. D 0.1 mm

Correct answer: 0.1 mm

Least count = 1 main-scale division - 1 vernier division = 1 mm - 0.9 mm = 0.1 mm. The 0.9 mm option is the length of one vernier division, not the difference that sets the least count.

Question 21 of 37 Easy

Reading the scale of a measuring cylinder from an angle instead of at eye level introduces which error?

  1. A Zero error
  2. B Parallax error
  3. C Calibration drift
  4. D Rounding error

Correct answer: Parallax error

Parallax error arises when the eye is not perpendicular to the scale, so the meniscus appears against the wrong graduation. Zero error is a fixed offset when the instrument should read zero and is unrelated to viewing angle.

Question 22 of 37 Easy

Which statistic is most commonly used to quantify the precision of a set of repeated measurements?

  1. A Arithmetic mean
  2. B Percent error
  3. C Correlation coefficient
  4. D Standard deviation

Correct answer: Standard deviation

Standard deviation measures how tightly repeated readings cluster around their mean, which is exactly what precision describes. Percent error compares a result with the accepted value and therefore describes accuracy, not precision.

Question 23 of 37 Hard

In ISO 5725 terminology, the closeness of the mean of a large number of results to the true value is called:

  1. A Trueness
  2. B Precision
  3. C Repeatability
  4. D Validity

Correct answer: Trueness

ISO 5725 splits accuracy into trueness (closeness of the mean to the true value) and precision (closeness of results to each other). Precision is tempting but describes scatter among results, not how close their average is to the truth.

Question 24 of 37 Medium

Precision measured by the same operator, with the same instrument and conditions, over a short time is called:

  1. A Reproducibility
  2. B Repeatability
  3. C Trueness
  4. D Linearity

Correct answer: Repeatability

Repeatability is precision under identical conditions over a short interval. Reproducibility is the commonly confused term, but it refers to precision when conditions such as laboratory, operator or instrument change.

Question 25 of 37 Hard

Precision of results when different laboratories, operators and instruments measure the same sample is called:

  1. A Repeatability
  2. B Intermediate precision
  3. C Reproducibility
  4. D Sensitivity

Correct answer: Reproducibility

Reproducibility describes agreement between results obtained under changed conditions such as different laboratories. Intermediate precision is tempting, but it covers variations within a single laboratory, such as different days or analysts.

Question 26 of 37 Medium

What is 2.5 x 3.42 reported to the correct number of significant figures?

  1. A 8.55
  2. B 8.6
  3. C 8.550
  4. D 9

Correct answer: 8.6

In multiplication the result keeps as many significant figures as the least precise factor; 2.5 has two, so 8.55 rounds to 8.6. Reporting 8.55 keeps three significant figures and overstates the precision of the data.

Question 27 of 37 Medium

What is 12.11 + 0.3 reported with the correct precision?

  1. A 12.4
  2. B 12.41
  3. C 12
  4. D 12.410

Correct answer: 12.4

In addition the result keeps the fewest decimal places of any term; 0.3 has one decimal place, so 12.41 becomes 12.4. Reporting 12.41 ignores that 0.3 is only known to the tenths place.

Question 28 of 37 Easy

Relative error of a measurement is calculated as:

  1. A True value / absolute error
  2. B Absolute error x true value
  3. C Absolute error / true value
  4. D Measured value - true value

Correct answer: Absolute error / true value

Relative error expresses the absolute error as a fraction of the true value, which lets errors in different-sized quantities be compared. Measured value minus true value is the absolute (signed) error itself, before it is scaled by the true value.

Question 29 of 37 Medium

Lengths of 5.0 +/- 0.1 cm and 3.0 +/- 0.2 cm are added. Using the simple rule of adding absolute uncertainties, what is the uncertainty of the sum?

  1. A +/- 0.1 cm
  2. B +/- 0.2 cm
  3. C +/- 0.02 cm
  4. D +/- 0.3 cm

Correct answer: +/- 0.3 cm

When quantities are added or subtracted, their absolute uncertainties add: 0.1 + 0.2 = 0.3 cm. Taking only the larger uncertainty of 0.2 cm underestimates the combined uncertainty.

Question 30 of 37 Medium

Under the simple worst-case rule, when two measured quantities are multiplied, their percentage uncertainties are:

  1. A Multiplied together
  2. B Subtracted
  3. C Averaged
  4. D Added together

Correct answer: Added together

For products and quotients, percentage (relative) uncertainties are added to give the percentage uncertainty of the result. Multiplying them is a common mistake that would make the uncertainty absurdly small.

Question 31 of 37 Hard

The side of a square is measured with a 1% uncertainty. What is the percentage uncertainty in its calculated area?

  1. A 1%
  2. B 4%
  3. C 2%
  4. D 0.5%

Correct answer: 2%

Area = side squared, and raising a quantity to a power multiplies its percentage uncertainty by that power, so 2 x 1% = 2%. Answering 1% overlooks that the side appears twice in the product.

Question 32 of 37 Easy

The smallest change in a quantity that an instrument can detect is called its:

  1. A Resolution
  2. B Accuracy
  3. C Range
  4. D Calibration

Correct answer: Resolution

Resolution is the smallest increment an instrument can distinguish, such as 0.01 g on a balance. Accuracy is different: a high-resolution instrument can still be inaccurate if it is miscalibrated.

Question 33 of 37 Easy

Comparing an instrument's readings against a known standard and adjusting it accordingly is called:

  1. A Validation
  2. B Calibration
  3. C Interpolation
  4. D Normalization

Correct answer: Calibration

Calibration checks an instrument against a reference standard and corrects it, removing systematic errors. Validation confirms that a whole method is fit for purpose rather than adjusting an instrument's readings.

Question 34 of 37 Medium

A micrometer reads +0.02 mm with its jaws fully closed. A reading of 5.36 mm should be corrected to:

  1. A 5.34 mm
  2. B 5.38 mm
  3. C 5.36 mm
  4. D 5.32 mm

Correct answer: 5.34 mm

A positive zero error means every reading is too high, so it is subtracted: 5.36 - 0.02 = 5.34 mm. Adding the zero error to get 5.38 mm doubles the mistake instead of removing it.

Question 35 of 37 Hard

A screw gauge has a pitch of 0.5 mm and 50 divisions on its circular scale. What is its least count?

  1. A 0.1 mm
  2. B 0.01 mm
  3. C 0.025 mm
  4. D 0.001 mm

Correct answer: 0.01 mm

Least count = pitch / number of circular-scale divisions = 0.5 mm / 50 = 0.01 mm. The 0.1 mm value is the least count of a typical vernier caliper, not of this screw gauge.

Question 36 of 37 Hard

The coefficient of variation expresses the precision of a data set as:

  1. A Mean divided by SD
  2. B Range divided by mean
  3. C SD minus the mean
  4. D SD divided by mean

Correct answer: SD divided by mean

The coefficient of variation is the standard deviation divided by the mean, usually multiplied by 100 to give a percentage, so that scatter can be compared across data sets with different magnitudes. Mean divided by SD is the inverse ratio, known as the signal-to-noise ratio.

Question 37 of 37 Medium

How many significant figures does an exact counted quantity, such as 12 eggs, have?

  1. A Exactly two
  2. B Exactly twelve
  3. C Infinitely many
  4. D Depends on the instrument

Correct answer: Infinitely many

Counted quantities and defined values are exact, so they have unlimited significant figures and never restrict a calculation's precision. Exactly two is tempting because 12 has two digits, but that rule applies only to measured values.

Keep practicing

More Scientific Processes MCQs

0 / 37 answered